The Veterinary Record
HOME CURRENT ISSUE TABLE OF CONTENTS ARCHIVE SEARCH SUBSCRIPTIONS JOBS FEEDBACK HELP
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow A correction has been published
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Jacobsen, S.
Right arrow Articles by Kjelgaard-Hansen, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jacobsen, S.
Right arrow Articles by Kjelgaard-Hansen, M.
The Veterinary Record 163:327-330 (2008)
© 2008 British Veterinary Association


Papers and Articles

Evaluation of a commercially available apparatus for measuring the acute phase protein serum amyloid A in horses

S. Jacobsen, DVM, PhD1 and M. Kjelgaard-Hansen, DVM, PhD2

1 Department of Large Animal Sciences, Faculty of Life Sciences, University of Copenhagen, Hoejbakkegaard Allé 5, 2630 Taastrup, Denmark
2 Department of Small Animal Clinical Sciences, Faculty of Life Sciences, University of Copenhagen, Goennegaardsvej 3, 1870 Frederiksberg C, Copenhagen, Denmark

The aim of this study was to investigate the reliability of an immunoturbidometric assay for measuring the acute phase protein serum amyloid A (SAA) in horses in clinical practice. The assay was compared to a previously validated assay, and overlap performance was assessed by measuring the concentration of SAA in clinically healthy horses and horses with inflammatory and non-inflammatory diseases. In pools of serum with low and high SAA concentrations the assay's intra-assay coefficients of variation were 11·7 per cent and 4·6 per cent, and its interassay coefficients of variation were 9·1 per cent and 5·6 per cent, respectively. Slight inaccuracies were observed, but they were negligible in comparison with the range of the SAA response. The assay systematically underestimated the concentrations of SAA in comparison with the results of the validated assay. The assay detected the expected difference in SAA concentrations between the healthy and diseased horses.